Skip to content

CE-210 Helical Flow Sensor & Display

CE-210 flow meter rated to +/- 0.5 or 1% FSD accuracy.

Flow Range (Across The Line Sizes)
5 to 10,000L/H
Accuracy (Standard Installation Position)
+/- 0.5 or 1% FSD
Max Pressure
up to 25 bar

Need a quote for CE-210?

Send the flow range, fluid and quantity; we reply with a price and lead time within one working day.

Summary

Overview

CE-210 Helical Flow Sensor & Display is a flow meter manufactured by Chintan Engineers for handling diesel and similar fluids.

On the catalog datasheet, accuracy is rated at +/- 0.5 or 1% FSD, and it is rated for a working pressure of up to 25 bar.

The connection size is Thread (M).

The source catalog does not list a specific statutory approval for this model; confirm current certification status with our sales team before specifying it for a regulated application.

Data

Specifications

Performance
Max Pressureup to 25bar
Accuracy (Standard Installation Position)+/- 0.5 or 1% FSD
Repeatability0.05%
Maximum Working Pressure2.5Mpa
Flow range (across the line sizes)5 to 10,000L/H
Fluid & ambient temperature-40 to 120°C
Mechanical
EnclosurePA66 + GF
RotorPA66/POM/PPS
ShaftHard Stainless Steel-316
Bearingcarbon/pom with hard S.S. BALL
ConnectionThread (M)
Electrical
Display ModeTwo row Liquid Crystal Display (LCD)
Sensor type (pulse output sensor)Hall / Reed sensor or pickup coil
Power voltage (pulse output sensor)5 to 24V DC
Low power voltage (pulse output sensor)2 to 5V DC
High electric level (pulse output sensor)higher than 4.5 VDC (input voltage 5 VDC)
Low electric level (pulse output sensor)lower than 0.5 VDC (input voltage 5 VDC)
Power voltage (battery operated meter)3.0V, lasts 1+ years
Power-fail protection (battery operated meter)totalizer count is retained when power drops
Power voltage (4-20mA output)24V DC
Output signal (4-20mA output)4 to 20mA

Source: the CE-210 catalogue datasheet. Details may change with ongoing development.

Options

Variants and options

Code What it changes
CE-210-004 1/4" BSP line size, 5-40-400 L/H, 4200 pulses/litre
CE-210-025 1.25" BSP line size, 100-1000-10000 L/H, 52 pulses/litre

Hose lengths, mountings and counter options are configured at order.

Compliance

Approvals and compliance

The catalogue sheet for this model does not list a statutory approval; it is built for in-house and captive use where a Legal Metrology stamp is not required.

For custody transfer, retail-style records or hazardous areas, ask us which model in the range carries the approval you need.

Quality and approvals

Where it works

Applications

Diesel Generator Sets

Generator fuel is easy to lose track of between refills, and unmetered day tanks make pilferage and over-consumption hard to catch. Metering fuel in and monitoring…

Recommended CE-121 CE-172

Industrial Plants

Process plants need to meter and batch fluids other than diesel: oils, chemicals, LPG and other liquids, often into a specific preset volume for a batch…

Recommended CE-136 CE-210

Fleet & Vehicle Depots

Depot refuelling for trucks and vehicles needs a metered, repeatable dispense with a printed or logged record, and increasingly a separate line for AdBlue/DEF alongside diesel.

Recommended CE-206 CE-133

Enquiry

Request a quote

Five fields. We reply with a price, a lead time and the variant that fits.

Prefilled from this page. Change it if you need a different model.
We reply on WhatsApp if you prefer.
Replies within one working day.

Answers

Questions

How accurate is this model?

The catalog rates it at +/- 0.5 or 1% FSD accuracy. Repeatability, where listed, is in the specification table.

Is this model PESO or Weights & Measures approved?

The catalog sheet we have does not list a specific PESO or Weights & Measures certificate for this model. Confirm current approval status with us before using it in a regulated retail or custody-transfer setting.

What flow range does it cover?

The catalog datasheet does not give a single flow-range figure for this model; see the specification table for the closest listed values.

What fluids is it compatible with?

It is built for diesel and similar fuels; check with us before using it on a fluid not covered in the catalog, since seal and body materials are fluid-specific.

What output or display options are available?

24 V DC, per the catalog.

What is the warranty on this product?

Chintan Engineers offers a standard manufacturer's warranty on this product; ask our sales team for the current warranty period and terms for this model.

See also

Related models

CE-211

CE-211 Vortex Flow Meter

CE-211 flow meter for metered fluid handling.

Pipe Type
Class 1.0 -40~+400
Temperature
-25~60
Humidity
5%~90%
CE-213

CE-213 Flameproof Flow Meter

CE-213 flow meter rated to ±0.5 % FSD accuracy.

Flow Range (Across The Sensor Sizes)
5 to 150,000 L/H
Accuracy (Standard Installation Position)
±0.5 % FSD
Maximum Working Pressure
10 MPa
WhatsApp Request a quote