Diesel Generator Sets
Generator fuel is easy to lose track of between refills, and unmetered day tanks make pilferage and over-consumption hard to catch. Metering fuel in and monitoring…
Recommended CE-121 CE-172
Fuel monitoring
Pumps & nozzles
Batching

CE-144 flow meter rated to ±0.5 or 1 % FSD accuracy.
Send the flow range, fluid and quantity; we reply with a price and lead time within one working day.
Summary
CE-144 SS Turbine Flow Meter is a flow meter manufactured by Chintan Engineers for handling diesel and similar fluids.
On the catalog datasheet, accuracy is rated at ±0.5 or 1 % FSD, and it is rated for a working pressure of 6 MPa.
The connection size is Thread (M/F) or flange.
The source catalog does not list a specific statutory approval for this model; confirm current certification status with our sales team before specifying it for a regulated application.
Data
| Performance | |
|---|---|
| Accuracy (standard installation position) | ±0.5 or 1% FSD |
| Repeatability | 0.1% |
| Maximum working pressure | 6MPa |
| Fluid & ambient temperature | -20 to 120°C |
| Flow range (model range CE-TFS-004 to CE-TFS-150) | 40 to 800,000L/H |
| Calibration pressure points | 0.5, 4 and 25bar |
| Mechanical | |
| Enclosure | S.S-304/S.S-316 |
| Rotor | S.S-304 / S.S - 316 |
| Npn Open Connector Connection | THREAD (M/F) OR FLANGE |
| Shaft | Hard stainless steel-316 with carbon bush |
| Electrical | |
| Power voltage (pulse output sensor) | 12V DC |
| Output signal (pulse output sensor) | NPN open connector |
| Connection | Thread (M/F) or flange |
| Power voltage (battery operated meter) | 3.3V, 10AH lithium, 5+ years |
| Display mode | Double row Liquid Crystal Display (LCD) |
| Power voltage (4-20mA output) | 24V DC |
| Output signal (4-20mA output) | 4 to 20mA |
| General | |
| High Electric Level | HIGH THAN 8 VDC( INPUT VOLTAGE 12 VDC) |
| Low Electric Level | LOWER THAN 0.8 VDC( INPUT VOLTAGE 12 VDC) |
Source: the CE-144 catalogue datasheet. Details may change with ongoing development.
Compliance
The catalogue sheet for this model does not list a statutory approval; it is built for in-house and captive use where a Legal Metrology stamp is not required.
For custody transfer, retail-style records or hazardous areas, ask us which model in the range carries the approval you need.
Where it works

Generator fuel is easy to lose track of between refills, and unmetered day tanks make pilferage and over-consumption hard to catch. Metering fuel in and monitoring…
Recommended CE-121 CE-172

Process plants need to meter and batch fluids other than diesel: oils, chemicals, LPG and other liquids, often into a specific preset volume for a batch…
Recommended CE-136 CE-210

Depot refuelling for trucks and vehicles needs a metered, repeatable dispense with a printed or logged record, and increasingly a separate line for AdBlue/DEF alongside diesel.
Recommended CE-206 CE-133
Files
Enquiry
Five fields. We reply with a price, a lead time and the variant that fits.
Answers
The catalog rates it at ±0.5 or 1 % FSD accuracy. Repeatability, where listed, is in the specification table.
The catalog sheet we have does not list a specific PESO or Weights & Measures certificate for this model. Confirm current approval status with us before using it in a regulated retail or custody-transfer setting.
The catalog datasheet does not give a single flow-range figure for this model; see the specification table for the closest listed values.
It is built for diesel and similar fuels; check with us before using it on a fluid not covered in the catalog, since seal and body materials are fluid-specific.
Double row Liquid Crystal Display (LCD), per the catalog.
Chintan Engineers offers a standard manufacturer's warranty on this product; ask our sales team for the current warranty period and terms for this model.
See also

CE-143 flow meter rated to ±0.5 or 1 % FSD accuracy.

CE-147 flow meter with a flow range of 120 L/min.