{"id":50324,"date":"2026-06-07T15:33:26","date_gmt":"2026-06-07T15:33:26","guid":{"rendered":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/"},"modified":"2026-06-07T15:33:26","modified_gmt":"2026-06-07T15:33:26","slug":"positive-displacement-vs-ultrasonic-diesel-flow-meters","status":"publish","type":"post","link":"https:\/\/chintanengineers.in\/kn\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/","title":{"rendered":"\u0c95\u0cc8\u0c97\u0cbe\u0cb0\u0cbf\u0c95\u0cbe \u0ca1\u0cc0\u0cb8\u0cc6\u0cb2\u0ccd \u0c9f\u0ccd\u0cb0\u0ccd\u0caf\u0cbe\u0c95\u0cbf\u0c82\u0c97\u0ccd\u200c\u0c97\u0cbe\u0c97\u0cbf PD vs \u0c85\u0cb2\u0ccd\u0c9f\u0ccd\u0cb0\u0cbe\u0cb8\u0cbe\u0ca8\u0cbf\u0c95\u0ccd \u0cab\u0ccd\u0cb2\u0ccb \u0cae\u0cc0\u0c9f\u0cb0\u0ccd\u200c\u0c97\u0cb3\u0cc1"},"content":{"rendered":"<div class=\"gfm-markdown\"><blockquote>\n<p>[!STAT]<\/p>\n<p><strong>\u20b91.35 Lakhs\/month<\/strong> \u2014 The average financial leak a single manufacturing plant suffers when tracking 5,000 liters of daily diesel throughput with a flow meter experiencing just a 1% calibration drift.<\/p>\n<\/blockquote>\n\n<p>I have spent 22 years crawling under storage tanks, inspecting bulk loading gantries, and calibrating flow measurement systems across India. From ONGC refineries to dust-choked crushing plants in GIDC industrial estates, the question I hear from plant engineers every single week is the same: <em>&quot;Vikram, why should I cut my fuel line to install a mechanical meter when I can just strap an ultrasonic sensor to the outside of the pipe?&quot;<\/em><\/p>\n\n<p>It&#039;s a fair question. Clamp-on ultrasonic flow meters seem like magic. No downtime, no plumbing, no pressure drop. But when you are tracking high-value refined fuels like diesel (HSD) for generator consumption, boiler firing, or fleet dispensing, &quot;convenience&quot; is the absolute wrong metric to optimize. Accountability is all that matters.<\/p>\n\n<p>When you select a meter, you&#039;re ultimately choosing between measuring actual physical volume (Positive Displacement) versus inferring velocity through acoustic physics (Ultrasonic). I always prefer to strip away the marketing fluff and look at the hard engineering data, Legal Metrology compliance, and real-world Indian operational realities. Let&#039;s look at why I strongly bias toward positive displacement for diesel accountability.<\/p>\n\n<h2>The Physics of Fuel Measurement: Trapping vs. Ping-Pong<\/h2>\n\n<p>Why do these technologies perform so differently in the field? It all comes down to the fluid mechanics happening inside the pipe.<\/p>\n\n<h3>Transit-Time Ultrasonic Measurement (The Inferred Method)<\/h3>\n<p>Clamp-on ultrasonic flow meters use the transit-time differential method. Two piezoelectric transducers are strapped to the outside of your MS (Mild Steel) or SS (Stainless Steel) pipe. One shoots an acoustic wave downstream, the other shoots upstream. The meter measures the time difference (\u0394t) it takes for the sound pulses to cross the fluid. Because sound travels faster moving with the flow and slower moving against it, the meter calculates fluid velocity. Multiply that velocity by the cross-sectional area of the pipe, and you get volumetric flow.<\/p>\n\n<p>Here is the main problem for industrial diesel tracking: the meter is completely blind to the actual inside of your pipe. It assumes the internal diameter ($D_i$) is perfectly uniform. It assumes the acoustic impedance of your pipe wall is constant. As anyone working in Indian industrial plants knows, older pipes are riddled with scaling, rust, weld slag, and varying wall thicknesses. Every micron of internal pipe scale alters the acoustic path, introducing a compounding error into your velocity calculation.<\/p>\n\n<h3>Positive Displacement Measurement (The Volumetric Method)<\/h3>\n<p>Positive Displacement (PD) meters are the accountants of the fluid mechanics world. They don&#039;t guess velocity. A PD meter forces the fluid to move through precision-machined measuring chambers. Whether it uses oval gears, rotary vanes, or oscillating pistons, the principle is identical: the meter divides the continuous flow into discrete, known volumetric segments (like a revolving door). <\/p>\n\n<p>It&#039;s simple math. Every rotation of the internal gear corresponds to an exact, physical volume of diesel. If the gear turns 100 times, exactly &#039;X&#039; liters have passed. There is no guesswork about pipe scaling, flow profiles, or acoustic reflections. <\/p>\n\n<blockquote>\n<p>[!TIP]<\/p>\n<p>I\u2019ve calibrated enough flow meters to know they don\u2019t belong anywhere near viscous fuels unless they are physically trapping the fluid. If you are doing mass balances on diesel generators or boilers, always trust physical volumetric separation over velocity inference.<\/p>\n<\/blockquote>\n\n\n<p><img src=\"https:\/\/chintanengineers.in\/wp-content\/smush-webp\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg.webp\" alt=\"Comparison of ultrasonic transit-time acoustic waves versus positive displacement volumetric measuring chambers\" loading=\"lazy\" decoding=\"async\" \/><\/p>\n\n\n<h2>Measurement Accuracy and Legal Metrology Compliance<\/h2>\n\n<p>When a procurement manager pushes back on the upfront cost of a high-accuracy PD meter, I point them straight to the Indian Legal Metrology Act and OIML R117 (Dynamic measuring systems for liquids other than water).<\/p>\n\n<p>If you are transferring custody of diesel\u2014meaning money is changing hands based on the meter reading, or you are claiming excise tax credits\u2014you legally require a meter that meets stringent accuracy classes.<\/p>\n\n<p><strong>Ultrasonic Meters in the Field:<\/strong><\/p>\n<p>Under pristine laboratory conditions on brand-new stainless steel pipes, a high-end clamp-on ultrasonic meter might claim \u00b11.0% accuracy. However, in an actual plant environment, ultrasonic accuracy typically degrades to \u00b12.0% to \u00b15.0%. The acoustic coupling gel used to bind the sensors to the pipe routinely dries out in 45\u00b0C Indian summers, completely dropping the signal. (I\u2019ve spent hours arguing with plant managers who thought a dried-out ultrasonic sensor just needed a recalibration instead of a fresh dab of grease.) Furthermore, ultrasonic meters struggle immensely at low flow rates (creeping flows) because the \u0394t becomes too small for the electronics to resolve accurately.<\/p>\n\n<p><strong>Positive Displacement Meters in the Field:<\/strong><\/p>\n<p>Because PD meters physically trap the liquid, they excel at high accuracy. This is exactly why we design units like the Chintan Engineers <strong>CE-113 High Accuracy Diesel Flow Meter<\/strong> to deliver a custody-transfer grade accuracy of \u00b10.2%. It features a robust aluminum body, Viton seals, and handles up to 10 BAR pressure. It comes with a calibrator adjustable exactly to 0.2% to satisfy Weights &amp; Measures inspectors. <\/p>\n\n<p>Even our standard digital PD meter, the CE-105, maintains \u00b10.2% accuracy. I don&#039;t care about brochure specifications; I care about repeatable, provable performance verified by master provers or volumetric test cans on the actual job site.<\/p>\n\n<blockquote>\n<p>[!WARNING]<\/p>\n<p><strong>Compliance Alert:<\/strong> You cannot legally use a clamp-on ultrasonic flow meter for custody transfer or commercial sale of petroleum products in India. The Legal Metrology Department requires meters that can be mechanically or electronically sealed to prevent tampering, conforming to IS 14883. You must use an approved positive displacement, turbine, or Coriolis meter.<\/p>\n<\/blockquote>\n\n<blockquote>\n<p>[!CTA]<\/p>\n<p><strong>Need Custody-Transfer Accuracy?<\/strong><\/p>\n<p>Stop losing fuel to inferred measurement errors. Upgrade to the CE-113 High Accuracy PD Meter with 0.2% calibration precision.<\/p>\n<p><a href=\"https:\/\/chintanengineers.in\/products\/fuel-flow-meter\/\">View Fuel Flow Meter Specs<\/a> | <a href=\"\/contact-us\/\">Get a Sizing Quote<\/a><\/p>\n<\/blockquote>\n\n<h2>Viscosity, Temperature, and Indian Plant Realities<\/h2>\n\n<p>Diesel is not a static fluid. Its kinematic viscosity changes dramatically with temperature. Ever tried pumping winter-grade diesel early in the morning? During a chilly January morning in Punjab, diesel is thick. During a scorching May afternoon in Gujarat, it thins out significantly. <\/p>\n\n<p><strong>How Ultrasonic Handles Viscosity:<\/strong><\/p>\n<p>Ultrasonic meters require you to input the fluid&#039;s kinematic viscosity to calculate the Reynolds number and correct the flow profile curve. If the temperature swings and the viscosity changes, but the meter&#039;s programmed parameters don&#039;t update dynamically (which clamp-on units rarely do without external temperature transmitters), your accuracy drifts immediately.<\/p>\n\n<p><strong>How Positive Displacement Handles Viscosity:<\/strong><\/p>\n<p>This is where physical volumetric trapping proves its worth. PD meters are essentially immune to upstream flow profile distortions and viscosity changes. In fact, a PD meter&#039;s accuracy actually <em>improves<\/em> slightly as fluid viscosity increases. Why? Because the thicker fluid creates a better hydraulic seal between the rotating gears and the measuring chamber wall, reducing &quot;volumetric slip&quot; (the tiny amount of fluid that sneaks past the gears without being measured).<\/p>\n\n<p>If you look at our <strong>CE-110 Diesel Flow Meter<\/strong> (a mechanical unit operating at 20-120 LPM with 0.5% accuracy), you&#039;ll see it is virtually independent of viscosity swings. You can dispense thin diesel or thick lubricating oil through the CE-110, and the volumetric displacement remains constant.<\/p>\n\n\n<p><img src=\"https:\/\/chintanengineers.in\/wp-content\/smush-webp\/2026\/06\/ce-110-mechanical-positive-displacement-flow-meter-installed-scaled.jpg.webp\" alt=\"CE-110 mechanical positive displacement flow meter installed on an industrial diesel boiler feed line\" loading=\"lazy\" decoding=\"async\" \/><\/p>\n\n\n<h2>TCO and ROI: The True Cost of Installation<\/h2>\n\n<p>The biggest argument for ultrasonic is the installation cost. &quot;No pipe cutting! No downtime!&quot; This is absolutely true. Installing a CE-113 or CE-105 positive displacement meter requires isolation valves, a pipeline shutdown, cutting flanges, and bolting the unit in place. It requires a strainer (filter) upstream to protect the precision gears from weld slag and debris.<\/p>\n\n<p>But let&#039;s run the actual math on Total Cost of Ownership (TCO) for an industrial boiler consuming 5,000 liters of diesel per day.<\/p>\n\n<ul>\n<li><strong>Throughput:<\/strong> 5,000 Liters \/ Day<\/li>\n<li><strong>Annual Volume:<\/strong> 1,500,000 Liters (assuming 300 working days)<\/li>\n<li><strong>Cost of Diesel:<\/strong> \u20b990 \/ Liter<\/li>\n<li><strong>Total Annual Fuel Value:<\/strong> \u20b913.5 Crores<\/li>\n<\/ul>\n\n<p><strong>Scenario A: Clamp-on Ultrasonic Meter<\/strong><\/p>\n<ul>\n<li>Capital + Install Cost: \u20b91,50,000<\/li>\n<li>Real-world average accuracy error: 2.0%<\/li>\n<li>Annual Untracked Fuel Value: \u20b927,00,000<\/li>\n<\/ul>\n\n<p><strong>Scenario B: CE-113 High Accuracy PD Meter with Strainer &amp; Air Eliminator<\/strong><\/p>\n<ul>\n<li>Capital + Install Cost (Plumbing &amp; Downtime): \u20b92,50,000<\/li>\n<li>Guaranteed Accuracy Error: 0.2%<\/li>\n<li>Annual Untracked Fuel Value: \u20b92,70,000<\/li>\n<\/ul>\n\n<p>By avoiding a \u20b91,00,000 plumbing job, the plant bleeds \u20b924.3 Lakhs in untracked, unaccounted fuel every single year. Two weeks. That is how fast the ROI kicks in on the intrusive positive displacement meter.<\/p>\n\n<p>If you are integrating these meters into fleet operations, I highly recommend reviewing our <a href=\"https:\/\/chintanengineers.in\/mobile-fuel-dispenser-engineering-standards\/\">Mobile Fuel Dispenser Engineering Standards<\/a> to ensure your pipework and pumping mechanisms are engineered to support 0.2% accuracy.<\/p>\n\n<blockquote>\n<p>[!NOTE]<\/p>\n<p><strong>The Entrained Air Problem:<\/strong> Diesel delivery trucks almost always push compressed air through the line at the end of a decanting run to empty the hoses. Ultrasonic meters read these air bubbles as solid fluid volume or fault out entirely. A custody-transfer PD system utilizes a mechanical Air Eliminator upstream of the meter, venting the air <em>before<\/em> it reaches the measuring chamber. You only pay for liquid, not wind.<\/p>\n<\/blockquote>\n\n<h2>Selection &amp; Sizing Guide: Industrial Diesel Meters<\/h2>\n\n<p>Don&#039;t guess when standardizing your plant&#039;s fuel accountability. You must match the measurement technology to the specific process loop. Below is the exact specification matrix we&#039;ve used at Chintan Engineers over the last two decades.<\/p>\n\n<table>\n<tr><td>Feature \/ Requirement<\/td><td>Clamp-on Ultrasonic<\/td><td>High-Accuracy PD (CE-113)<\/td><td>Standard Digital PD (CE-105)<\/td><td>Mechanical PD (CE-110)<\/td><\/tr>\n<tr><td>:&#8212;<\/td><td>:&#8212;<\/td><td>:&#8212;<\/td><td>:&#8212;<\/td><td>:&#8212;<\/td><\/tr>\n<tr><td><strong>Measuring Principle<\/strong><\/td><td>Inferred Velocity (Transit-Time)<\/td><td>Volumetric Trapping<\/td><td>Volumetric Trapping<\/td><td>Volumetric Trapping<\/td><\/tr>\n<tr><td><strong>Accuracy<\/strong><\/td><td>\u00b12.0% to \u00b15.0% (Field)<\/td><td>\u00b10.2% (Custody Grade)<\/td><td>\u00b10.2%<\/td><td>\u00b10.5%<\/td><\/tr>\n<tr><td><strong>Flow Range Limit<\/strong><\/td><td>High velocities only<\/td><td>25 \u2013 1300 L\/min<\/td><td>Wide flow ranges<\/td><td>20 \u2013 120 L\/min<\/td><\/tr>\n<tr><td><strong>Pressure Drop<\/strong><\/td><td>Zero<\/td><td>Low (&lt; 0.5 Bar)<\/td><td>Low (&lt; 0.5 Bar)<\/td><td>Low<\/td><\/tr>\n<tr><td><strong>Viscosity Handling<\/strong><\/td><td>Requires recalibration<\/td><td>Independent &amp; Excellent<\/td><td>Independent &amp; Excellent<\/td><td>Independent &amp; Excellent<\/td><\/tr>\n<tr><td><strong>Custody Transfer \/ BIS<\/strong><\/td><td>Not Approved<\/td><td>Approved \/ Sealable<\/td><td>Approved \/ Sealable<\/td><td>Internal accounting<\/td><\/tr>\n<tr><td><strong>Output Options<\/strong><\/td><td>4-20mA, Modbus<\/td><td>Printer, Pulse, Mechanical<\/td><td>Pulse, Digital Display<\/td><td>4-Digit Mechanical Reset<\/td><\/tr>\n<tr><td><strong>Ideal Plant Location<\/strong><\/td><td>Chilled water, large effluent lines<\/td><td>Bulk fuel receipt, Gantries<\/td><td>Generator consumption loops<\/td><td>Small day-tanks, lube oils<\/td><\/tr>\n<\/table>\n\n\n<p><img src=\"https:\/\/chintanengineers.in\/wp-content\/smush-webp\/2026\/06\/engineering-selection-guide-and-blueprint-for-industrial-die-scaled.jpg.webp\" alt=\"Engineering selection guide and blueprint for industrial diesel flow meters\" loading=\"lazy\" decoding=\"async\" \/><\/p>\n\n\n<h2>Installation &amp; Maintenance: Doing it Right the First Time<\/h2>\n\n<p>If you&#039;re going to commit to the positive displacement route for your liquid batching or fuel tracking, do it right. The installation physics matter. I have seen perfectly good CE-105 meters destroyed within 48 hours because a contractor skipped the pre-commissioning flush (you have no idea how often I see this).<\/p>\n\n<ol>\n<li><strong>Filtration is Non-Negotiable:<\/strong> PD meters have extremely tight tolerances between the rotating components and the casing. A single piece of welding slag or a rusted pipe flake will jam the meter. You must install a Y-strainer or basket strainer (typically 100 mesh for diesel) immediately upstream of the meter.<\/li>\n<li><strong>Air Elimination:<\/strong> As mentioned earlier, air in the line causes over-registration. If you are pumping from an underground tank or receiving from a tanker truck, an air separator must be installed before the meter.<\/li>\n<li><strong>No Straight Run Required:<\/strong> Unlike ultrasonic or turbine meters which require 10x pipe diameters of straight run upstream to condition the flow profile, PD meters do not care about flow profiles. You can bolt a CE-110 directly to a 90-degree elbow without losing accuracy. This makes them exceptionally valuable in cramped diesel day-tank enclosures.<\/li>\n<li><strong>PLC Integration:<\/strong> For automated processes, you need pulse outputs. If you are experiencing issues where your SCADA system totals do not match your meter totals, read my deep dive on how to <a href=\"https:\/\/chintanengineers.in\/liquid-batching-system-troubleshooting-guide\/\">Troubleshoot Liquid Batching Systems<\/a> to resolve pulse-scaling mismatches.<\/li>\n<\/ol>\n\n<blockquote>\n<p>[!CTA]<\/p>\n<p><strong>Upgrading Your Generator Fuel Lines?<\/strong><\/p>\n<p>Integrate precise fuel consumption data directly into your plant SCADA. Our CE-105 Digital Flow Meters come pulse-ready for seamless PLC batching.<\/p>\n<p><a href=\"https:\/\/chintanengineers.in\/products\/fuel-flow-meter\/\">Explore the CE-105 Specs<\/a> | <a href=\"\/contact-us\/\">Request Technical Support<\/a><\/p>\n<\/blockquote>\n\n<h2>Frequently Asked Questions<\/h2>\n\n<h3>Why does my ultrasonic flow meter show flow when the diesel pump is off?<\/h3>\n<p>This is a common issue known as &quot;zero drift.&quot; Vibrations from nearby machinery, thermal expansion of the pipe, or acoustic noise in the pipeline can be misinterpreted by the ultrasonic transducers as fluid movement. Positive displacement meters physically cannot rotate without fluid pushing them, entirely eliminating phantom flow readings.<\/p>\n\n<h3>Can I use the CE-110 mechanical meter for unloading diesel from a bulk tanker?<\/h3>\n<p>No. The CE-110 is rated for 20-120 LPM, which is too slow for bulk tanker unloading (which typically requires 400 to 800 LPM). For tanker unloading, you must use the CE-113 high-accuracy bulk meter, which handles up to 1300 LPM and features the necessary air elimination equipment for decanting operations.<\/p>\n\n<h3>How often do positive displacement meters require calibration?<\/h3>\n<p>Under the Legal Metrology Act, custody transfer meters must be verified and stamped annually. For internal plant accounting, I recommend calibrating your PD meter every 12 to 18 months, or after 1,000,000 liters of throughput. If the diesel is clean and well-filtered, calibration drift is exceptionally minimal.<\/p>\n\n<h3>Do PD meters cause a high pressure drop in the system?<\/h3>\n<p>While intrusive, modern PD meters are designed with incredibly low friction bearings. The CE-113 and CE-105 models typically introduce less than 0.3 to 0.5 BAR of pressure drop at maximum flow, which is easily handled by standard centrifugal or gear pumps used in fuel transfer.<\/p>\n\n<h3>What happens if the acoustic gel on an ultrasonic meter dries out?<\/h3>\n<p>The acoustic coupling paste is essential to transmit the sound wave from the sensor through the pipe wall. In dusty, hot industrial environments (like cement plants or steel mills), this gel degrades rapidly. When it dries out, the signal-to-noise ratio drops, the meter faults out, and you lose your flow reading entirely. Clamp-on systems require constant preventative maintenance to reapply this couplant.<\/p>\n\n<h3>Can Chintan Engineers integrate ticket printers with these meters?<\/h3>\n<p>Yes. The CE-113 High Accuracy Diesel Flow Meter is frequently supplied in a custody-transfer build that includes a mechanical preset register and a Veeder-Root style ticket printer. This generates an immediate, physical hard-copy receipt for every bulk loading or unloading batch.<\/p>\n\n\n<p><img src=\"https:\/\/chintanengineers.in\/wp-content\/smush-webp\/2026\/06\/ce-113-high-accuracy-positive-displacement-meter-printing-a--scaled.jpg.webp\" alt=\"CE-113 high accuracy positive displacement meter printing a custody transfer batch ticket\" loading=\"lazy\" decoding=\"async\" \/><\/p>\n\n\n<h2>Final Engineering Verdict<\/h2>\n\n<p>Here is the bottom line: If you are measuring cooling water, effluent discharge, or running a temporary diagnostic flow study across massive pipeline diameters, buy an ultrasonic meter. It is the right tool for that specific job.<\/p>\n\n<p>But if you are tracking high-value refined hydrocarbons like diesel, furnace oil, or lubricants\u2014where every 0.1% of error hits your operational expenditure directly\u2014you must measure physically, not theoretically.<\/p>\n\n<p>Why gamble your fuel accountability on acoustic guesses when you can physically trap and count every single drop? The cost of cutting a pipe and bolting in a <strong>CE-113 High Accuracy Diesel Flow Meter<\/strong> is a drop in the bucket compared to the cost of 2% unmeasured fuel loss over a 10-year operational lifespan. Use precision strainers, implement mechanical air elimination, and rely on the uncheatable physics of positive displacement.<\/p>\n\n<blockquote>\n<p>[!CTA]<\/p>\n<p><strong>Stop Guessing Your Fuel Consumption.<\/strong><\/p>\n<p>Equip your plant with BIS-compliant, positive displacement flow measurement engineered for Indian industrial conditions.<\/p>\n<p><a href=\"https:\/\/chintanengineers.in\/products\/fuel-flow-meter\/\">Browse All Fuel Flow Meters<\/a> | <a href=\"\/contact-us\/\">Contact Vikram for a Sizing Consultation<\/a><\/p>\n<\/blockquote>\n\n<\/div>\n\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Why does my ultrasonic flow meter show flow when the diesel pump is off?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"This is a common issue known as zero drift. Vibrations from nearby machinery, thermal expansion of the pipe, or acoustic noise in the pipeline can be misinterpreted by the ultrasonic transducers as fluid movement. Positive displacement meters physically cannot rotate without fluid pushing them, entirely eliminating phantom flow readings.\"}},{\"@type\":\"Question\",\"name\":\"Can I use the CE-110 mechanical meter for unloading diesel from a bulk tanker?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The CE-110 is rated for 20-120 LPM, which is too slow for bulk tanker unloading (which typically requires 400 to 800 LPM). For tanker unloading, you must use the CE-113 high-accuracy bulk meter, which handles up to 1300 LPM and features the necessary air elimination equipment for decanting operations.\"}},{\"@type\":\"Question\",\"name\":\"How often do positive displacement meters require calibration?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Under the Legal Metrology Act, custody transfer meters must be verified and stamped annually. For internal plant accounting, it is recommended to calibrate your PD meter every 12 to 18 months, or after 1,000,000 liters of throughput. If the diesel is clean and well-filtered, calibration drift is exceptionally minimal.\"}},{\"@type\":\"Question\",\"name\":\"Do PD meters cause a high pressure drop in the system?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"While intrusive, modern PD meters are designed with incredibly low friction bearings. The CE-113 and CE-105 models typically introduce less than 0.3 to 0.5 BAR of pressure drop at maximum flow, which is easily handled by standard centrifugal or gear pumps used in fuel transfer.\"}},{\"@type\":\"Question\",\"name\":\"What happens if the acoustic gel on an ultrasonic meter dries out?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The acoustic coupling paste is essential to transmit the sound wave from the sensor through the pipe wall. In dusty, hot industrial environments, this gel degrades rapidly. When it dries out, the signal-to-noise ratio drops, the meter faults out, and you lose your flow reading entirely. Clamp-on systems require constant preventative maintenance to reapply this couplant.\"}},{\"@type\":\"Question\",\"name\":\"Can Chintan Engineers integrate ticket printers with these meters?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The CE-113 High Accuracy Diesel Flow Meter is frequently supplied in a custody-transfer build that includes a mechanical preset register and a Veeder-Root style ticket printer. This generates an immediate, physical hard-copy receipt for every bulk loading or unloading batch.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":50321,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_yoast_wpseo_focuskw":"pd flow meter vs ultrasonic","_yoast_wpseo_title":"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking","_yoast_wpseo_metadesc":"A 22-year flow engineer compares PD and ultrasonic flow meters for diesel tracking. Learn why custody-transfer demands mechanical measurement.","_yoast_wpseo_canonical":"","_eb_attr":"","_n8n_st_send_on_update":false,"_yoast_wpseo_keywordsynonyms":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-50324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking<\/title>\n<meta name=\"description\" content=\"A 22-year flow engineer compares PD and ultrasonic flow meters for diesel tracking. Learn why custody-transfer demands mechanical measurement.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chintanengineers.in\/kn\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking\" \/>\n<meta property=\"og:description\" content=\"A 22-year flow engineer compares PD and ultrasonic flow meters for diesel tracking. Learn why custody-transfer demands mechanical measurement.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chintanengineers.in\/kn\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/\" \/>\n<meta property=\"og:site_name\" content=\"Chintan Engineers\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-07T15:33:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"573\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chintan Engineers Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chintan Engineers Staff\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/\"},\"author\":{\"name\":\"Chintan Engineers Staff\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#\\\/schema\\\/person\\\/4588f04835a992d9f7724b976b4ab59f\"},\"headline\":\"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking\",\"datePublished\":\"2026-06-07T15:33:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/\"},\"wordCount\":9,\"publisher\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"kn\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/\",\"name\":\"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg\",\"datePublished\":\"2026-06-07T15:33:26+00:00\",\"description\":\"A 22-year flow engineer compares PD and ultrasonic flow meters for diesel tracking. Learn why custody-transfer demands mechanical measurement.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#breadcrumb\"},\"inLanguage\":\"kn\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg\",\"width\":1024,\"height\":573},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/positive-displacement-vs-ultrasonic-diesel-flow-meters\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chintanengineers.in\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#website\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/\",\"name\":\"Chintan Engineers\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chintanengineers.in\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"kn\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#organization\",\"name\":\"Chintan Engineers\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-Achievers-Chintan-Engineers-Combined-Logo-2-e1760938887596.png\",\"contentUrl\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/cropped-Achievers-Chintan-Engineers-Combined-Logo-2-e1760938887596.png\",\"width\":337,\"height\":200,\"caption\":\"Chintan Engineers\"},\"image\":{\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/#\\\/schema\\\/person\\\/4588f04835a992d9f7724b976b4ab59f\",\"name\":\"Chintan Engineers Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"kn\",\"@id\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/bd9\\\/bd97a6feb2eff6182e08401c413f8db7x96.jpg\",\"url\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/bd9\\\/bd97a6feb2eff6182e08401c413f8db7x96.jpg\",\"contentUrl\":\"https:\\\/\\\/chintanengineers.in\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/bd9\\\/bd97a6feb2eff6182e08401c413f8db7x96.jpg\",\"caption\":\"Chintan Engineers Staff\"},\"url\":\"https:\\\/\\\/chintanengineers.in\\\/kn\\\/author\\\/chintan2181997\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0c95\u0cc8\u0c97\u0cbe\u0cb0\u0cbf\u0c95\u0cbe \u0ca1\u0cc0\u0cb8\u0cc6\u0cb2\u0ccd \u0c9f\u0ccd\u0cb0\u0ccd\u0caf\u0cbe\u0c95\u0cbf\u0c82\u0c97\u0ccd\u200c\u0c97\u0cbe\u0c97\u0cbf PD vs \u0c85\u0cb2\u0ccd\u0c9f\u0ccd\u0cb0\u0cbe\u0cb8\u0cbe\u0ca8\u0cbf\u0c95\u0ccd \u0cab\u0ccd\u0cb2\u0ccb \u0cae\u0cc0\u0c9f\u0cb0\u0ccd\u200c\u0c97\u0cb3\u0cc1","description":"22 \u0cb5\u0cb0\u0ccd\u0cb7\u0ca6 \u0cab\u0ccd\u0cb2\u0ccb \u0c8e\u0c82\u0c9c\u0cbf\u0ca8\u0cbf\u0caf\u0cb0\u0ccd \u0ca1\u0cc0\u0cb8\u0cc6\u0cb2\u0ccd \u0c9f\u0ccd\u0cb0\u0ccd\u0caf\u0cbe\u0c95\u0cbf\u0c82\u0c97\u0ccd\u200c\u0c97\u0cbe\u0c97\u0cbf \u0caa\u0cbf\u0ca1\u0cbf \u0cae\u0ca4\u0ccd\u0ca4\u0cc1 \u0c85\u0cb2\u0ccd\u0c9f\u0ccd\u0cb0\u0cbe\u0cb8\u0cbe\u0ca8\u0cbf\u0c95\u0ccd \u0cab\u0ccd\u0cb2\u0ccb \u0cae\u0cc0\u0c9f\u0cb0\u0ccd\u200c\u0c97\u0cb3\u0ca8\u0ccd\u0ca8\u0cc1 \u0cb9\u0ccb\u0cb2\u0cbf\u0cb8\u0cc1\u0ca4\u0ccd\u0ca4\u0cbe\u0cb0\u0cc6. \u0c95\u0cb8\u0ccd\u0c9f\u0ca1\u0cbf-\u0cb5\u0cb0\u0ccd\u0c97\u0cbe\u0cb5\u0ca3\u0cc6\u0c97\u0cc6 \u0caf\u0cbe\u0c82\u0ca4\u0ccd\u0cb0\u0cbf\u0c95 \u0cae\u0cbe\u0caa\u0ca8 \u0c8f\u0c95\u0cc6 \u0cac\u0cc7\u0c95\u0cc1 \u0c8e\u0c82\u0ca6\u0cc1 \u0ca4\u0cbf\u0cb3\u0cbf\u0caf\u0cbf\u0cb0\u0cbf.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chintanengineers.in\/kn\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/","og_locale":"en_US","og_type":"article","og_title":"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking","og_description":"A 22-year flow engineer compares PD and ultrasonic flow meters for diesel tracking. Learn why custody-transfer demands mechanical measurement.","og_url":"https:\/\/chintanengineers.in\/kn\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/","og_site_name":"Chintan Engineers","article_published_time":"2026-06-07T15:33:26+00:00","og_image":[{"width":1024,"height":573,"url":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg","type":"image\/jpeg"}],"author":"Chintan Engineers Staff","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Chintan Engineers Staff"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#article","isPartOf":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/"},"author":{"name":"Chintan Engineers Staff","@id":"https:\/\/chintanengineers.in\/#\/schema\/person\/4588f04835a992d9f7724b976b4ab59f"},"headline":"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking","datePublished":"2026-06-07T15:33:26+00:00","mainEntityOfPage":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/"},"wordCount":9,"publisher":{"@id":"https:\/\/chintanengineers.in\/#organization"},"image":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#primaryimage"},"thumbnailUrl":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg","articleSection":["Blog"],"inLanguage":"kn"},{"@type":"WebPage","@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/","url":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/","name":"\u0c95\u0cc8\u0c97\u0cbe\u0cb0\u0cbf\u0c95\u0cbe \u0ca1\u0cc0\u0cb8\u0cc6\u0cb2\u0ccd \u0c9f\u0ccd\u0cb0\u0ccd\u0caf\u0cbe\u0c95\u0cbf\u0c82\u0c97\u0ccd\u200c\u0c97\u0cbe\u0c97\u0cbf PD vs \u0c85\u0cb2\u0ccd\u0c9f\u0ccd\u0cb0\u0cbe\u0cb8\u0cbe\u0ca8\u0cbf\u0c95\u0ccd \u0cab\u0ccd\u0cb2\u0ccb \u0cae\u0cc0\u0c9f\u0cb0\u0ccd\u200c\u0c97\u0cb3\u0cc1","isPartOf":{"@id":"https:\/\/chintanengineers.in\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#primaryimage"},"image":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#primaryimage"},"thumbnailUrl":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg","datePublished":"2026-06-07T15:33:26+00:00","description":"22 \u0cb5\u0cb0\u0ccd\u0cb7\u0ca6 \u0cab\u0ccd\u0cb2\u0ccb \u0c8e\u0c82\u0c9c\u0cbf\u0ca8\u0cbf\u0caf\u0cb0\u0ccd \u0ca1\u0cc0\u0cb8\u0cc6\u0cb2\u0ccd \u0c9f\u0ccd\u0cb0\u0ccd\u0caf\u0cbe\u0c95\u0cbf\u0c82\u0c97\u0ccd\u200c\u0c97\u0cbe\u0c97\u0cbf \u0caa\u0cbf\u0ca1\u0cbf \u0cae\u0ca4\u0ccd\u0ca4\u0cc1 \u0c85\u0cb2\u0ccd\u0c9f\u0ccd\u0cb0\u0cbe\u0cb8\u0cbe\u0ca8\u0cbf\u0c95\u0ccd \u0cab\u0ccd\u0cb2\u0ccb \u0cae\u0cc0\u0c9f\u0cb0\u0ccd\u200c\u0c97\u0cb3\u0ca8\u0ccd\u0ca8\u0cc1 \u0cb9\u0ccb\u0cb2\u0cbf\u0cb8\u0cc1\u0ca4\u0ccd\u0ca4\u0cbe\u0cb0\u0cc6. \u0c95\u0cb8\u0ccd\u0c9f\u0ca1\u0cbf-\u0cb5\u0cb0\u0ccd\u0c97\u0cbe\u0cb5\u0ca3\u0cc6\u0c97\u0cc6 \u0caf\u0cbe\u0c82\u0ca4\u0ccd\u0cb0\u0cbf\u0c95 \u0cae\u0cbe\u0caa\u0ca8 \u0c8f\u0c95\u0cc6 \u0cac\u0cc7\u0c95\u0cc1 \u0c8e\u0c82\u0ca6\u0cc1 \u0ca4\u0cbf\u0cb3\u0cbf\u0caf\u0cbf\u0cb0\u0cbf.","breadcrumb":{"@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#breadcrumb"},"inLanguage":"kn","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/"]}]},{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#primaryimage","url":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg","contentUrl":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2026\/06\/comparison-of-ultrasonic-transit-time-acoustic-waves-versus--scaled.jpg","width":1024,"height":573},{"@type":"BreadcrumbList","@id":"https:\/\/chintanengineers.in\/positive-displacement-vs-ultrasonic-diesel-flow-meters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chintanengineers.in\/"},{"@type":"ListItem","position":2,"name":"PD vs Ultrasonic Flow Meters for Industrial Diesel Tracking"}]},{"@type":"WebSite","@id":"https:\/\/chintanengineers.in\/#website","url":"https:\/\/chintanengineers.in\/","name":"\u0c9a\u0cbf\u0c82\u0ca4\u0ca8\u0ccd \u0c87\u0c82\u0c9c\u0cbf\u0ca8\u0cbf\u0caf\u0cb0\u0ccd\u0cb8\u0ccd","description":"","publisher":{"@id":"https:\/\/chintanengineers.in\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chintanengineers.in\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"kn"},{"@type":"Organization","@id":"https:\/\/chintanengineers.in\/#organization","name":"\u0c9a\u0cbf\u0c82\u0ca4\u0ca8\u0ccd \u0c87\u0c82\u0c9c\u0cbf\u0ca8\u0cbf\u0caf\u0cb0\u0ccd\u0cb8\u0ccd","url":"https:\/\/chintanengineers.in\/","logo":{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/chintanengineers.in\/#\/schema\/logo\/image\/","url":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2025\/10\/cropped-Achievers-Chintan-Engineers-Combined-Logo-2-e1760938887596.png","contentUrl":"https:\/\/chintanengineers.in\/wp-content\/uploads\/2025\/10\/cropped-Achievers-Chintan-Engineers-Combined-Logo-2-e1760938887596.png","width":337,"height":200,"caption":"Chintan Engineers"},"image":{"@id":"https:\/\/chintanengineers.in\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/chintanengineers.in\/#\/schema\/person\/4588f04835a992d9f7724b976b4ab59f","name":"\u0c9a\u0cbf\u0c82\u0ca4\u0ca8\u0ccd \u0c8e\u0c82\u0c9c\u0cbf\u0ca8\u0cbf\u0caf\u0cb0\u0ccd\u0cb8\u0ccd \u0cb8\u0cbf\u0cac\u0ccd\u0cac\u0c82\u0ca6\u0cbf","image":{"@type":"ImageObject","inLanguage":"kn","@id":"https:\/\/chintanengineers.in\/wp-content\/wphb-cache\/gravatar\/bd9\/bd97a6feb2eff6182e08401c413f8db7x96.jpg","url":"https:\/\/chintanengineers.in\/wp-content\/wphb-cache\/gravatar\/bd9\/bd97a6feb2eff6182e08401c413f8db7x96.jpg","contentUrl":"https:\/\/chintanengineers.in\/wp-content\/wphb-cache\/gravatar\/bd9\/bd97a6feb2eff6182e08401c413f8db7x96.jpg","caption":"Chintan Engineers Staff"},"url":"https:\/\/chintanengineers.in\/kn\/author\/chintan2181997\/"}]}},"_links":{"self":[{"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/posts\/50324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/comments?post=50324"}],"version-history":[{"count":0,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/posts\/50324\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/media\/50321"}],"wp:attachment":[{"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/media?parent=50324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/categories?post=50324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chintanengineers.in\/kn\/wp-json\/wp\/v2\/tags?post=50324"}],"curies":[{"name":"\u0ca1\u0cac\u0ccd\u0cb2\u0ccd\u0caf\u0cc2\u0caa\u0cbf","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}